OKD-HZ41C Hall flow meter 1/4''-paypal accept
INTRODUCTION
Introduction
1, environmental protection design, food grade material POM, small, practical, and can be arbitrary Angle regulation;
2, double end for 6 mm intubation type structure, connect more convenient;
3, hall element for Japan imports, sensitive and reliable;
4, flow range: 0.1-3 L/min, working voltage: DC3-18 V, rated voltage DC5V;
5, output voltage (rated DC5V) : high level 4.5 V above, low level 0.5 V the following; Pulse output occupies emptiescompared to 50-10%;
6, designed for small flow and medicine machinery make water flow sensor, but also be used for electrical and mechanical equipment.
Electronic character
NO | Item | Examination requirement |
1 | Appearance | Clean and beautiful, smooth without burr, without off color |
2 | Water pressure resistance performance | 0.85 MPa pressure has no slack phenomenon, and parts no crack, relaxation, inflation, and deformation anomaly |
3 | Operating voltage range | DC3-18V, rate 5VDC |
4 | Maximum operating current | 15mA |
5 | The output pulse high level | In 5 V rated voltage, the output of the high level requirements in 4.5 V above |
6 | The output pulse low level | In 5 V rated voltage, the output of the low level requirements in 0.5 V the following |
7 | The output pulse duty ratio | In the rated voltage, the output pulse occupies emptiescompared to 50%-10% |
8 | Flow pulse characteristics | See flow parameters and pulse cross-references |
9 | Insulating property | Dielectric resistance>100MΩ |
10 | Electrical strength | AC500V 50Hz(Don't breakdown or flash winding) |
11 | Electrical strength(80°C) | In 80 °C temperature placed in 72 hours, in the environmental temperature back after 1 hour the accuracy of measurement requirements within the plus or minus 5% |
12 | Cold resistance(-20°C) | In 20 °C temperature placed in-72 hours, in the environmental temperature back after 1 hour the accuracy of measurement requirements within the plus or minus 5% |
13 | Mode of connection | Red: the positive, black: negative, yellow: pulse signal |
If you need data sheet or other help could chat me online skype:jolenchong